Look here when something in Cable Tracing doesn’t work the way you expect. For problems listed in the Issues panel, see Find and fix issues.

Starting Cable Tracing

Cause: Cable Tracing is turned on separately for each organization, and it isn’t on for yours.Fix:
  1. Ask Cloneable support to turn it on.
  2. When it’s on, open Utility Map, choose one job and click Cable Tracing.
For the full checklist, see Prepare a job for Cable Tracing.
Cause: this job’s configuration has no pick list.Fix: ask an admin to add one under Settings → Configurations → Pick list, using your DDS standards or your SPIDAcalc client file.
Cause: the pole has no measurement photo, or the phone that captured it hasn’t finished syncing.Fix: ask the crew to open the Cloneable app and let it sync.

Clicking and cards

Fix:
  1. In the bar at the bottom of the map, click Undo.
  2. Scroll on the photo to zoom in, and click the part again.
  3. To zoom back out, click Fit photo.
Cause: Cloneable needs the spot where the arm mounts on the pole. This applies to a double crossarm and to a crossarm on the side of the pole facing the camera.Fix: click the pole at the height of the bolt that holds the arm.
Cause: Cloneable can’t tell which wire from the previous pole is on this part.Fix: choose the wire from the list. To change it later, click Another wire… on the card.
Cause: the photo was taken from the other side of the line.Fix: in the bar, click Flip. The map turns so the cards match the photos, and the photo itself is never mirrored. If two wires show as crossed, compare both poles with their photos before you click Swap them.
Fix: click Not here, click the photo, and choose the framing that’s on the pole.
Fix: in the wire list, choose the option that matches the wire:

Heights

Cause: the photo isn’t calibrated, or heights are turned off for the configuration.Fix: calibrate the photo, or type the height on the part’s card. To turn heights on, an admin can turn on Annotator heights in the configuration’s Project setup.
Fix:
  1. Check the wire’s heights at both poles.
  2. Check which wire you clicked on the midspan photo.
  3. Look for Swapped? tags. See Common issues.
A wire on a post or bracket shows and exports at the height of the post’s bolt, because that’s where the part mounts.

Saving

Cause: Cloneable saves when you stop making changes and when you leave Cable Tracing.Fix: wait a few seconds.
Cause: a save didn’t go through, so Cloneable is trying again.Fix: keep the tab open. If a Not saved row appears in the Issues panel, Cloneable couldn’t save that change. Click the row to save again.
Fix: in the bar, click Try again before you change anything. Changes you make before the trace loads aren’t saved.

Exports

Cause: the wire has no conductor from your standards, or it’s on only one pole.Fix: open the export dialog and read the warning, which names the pole. See Common DDS warnings.
Cause: the arm isn’t in a framing.Fix: click the Not in a framing tag on the arm and choose a framing.
Cause: the guy wire isn’t tied to an anchor, or the pole has no anchor on the map.Fix: if the anchor is missing, add it on the map. Then tie the guy wire to it on the guy wire’s card.
Cause: an edit is still saving, or an edit didn’t save.Fix: wait a moment, and then click Check again. If an edit didn’t save, make the edit again, or reload the map to discard it.

Contact support

If the problem continues, send us a message from the chat in Cloneable. Include the job’s name and the exact wording you see on screen.